Ricoh OR-C1 Field Service Manual page 423

Table of Contents

Advertisement

No.
Type
Fusing temperature warm-up error (end)
The fusing temperature did not reach the standby temperature within 20 sec. at the
center of the hot roller after the main switch turned on.
• Fusing thermistor defective or out of position
• Fusing lamp disconnected
552
A
• Thermistor defective
• Fusing lamp defective
1. Check the fusing thermistor is set correctly.
2. Check the fusing lamp is connected correctly.
3. Replace the fusing thermistor.
4. Replace the fusing lamp.
No.
Type
Fusing overheat error 1 (end)
The fusing thermistor detected a fusing temperature over 230°C for 5 sec. at the
center of the hot roller.
• TRIAC short on PSU (PSU defective)
553
A
• BCU board defective
• Fusing thermistor defective
1. Replace the PSU.
2. Replace the BCU board.
3. Replace the thermistor.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Service Call Conditions