Temp Inside the Machine
Displays the temperature measured inside the machine just after power-on (by the
thermistor on the BCU board) the last time that the fusing unit was less than 40°C just
25*
after the machine was switched on.
The transfer current is corrected in accordance with this value.
[0 to 99 / 20 / 1 A /step]
2302*
Transfer Current Switch Timing
Transfer Current Switch Timing Lead Edge
1
Adjusts the transfer current switch timing based on FGATE assert.
[–10 to 10 / 0 / 1 mm]
Transfer Current Switch Timing Trail Edge
2
Adjusts the transfer current switch timing based on FGATE negate.
[–10 to 10 / 0 / 1 mm]
2303*
Transfer Roller Cleaning Bias
Positive
Adjusts the positive current of the paper transfer roller for cleaning the paper transfer
1
roller.
[0 to 20 / 10 / 1 A]
Negative
Adjusts the negative current of the paper transfer roller for cleaning the paper transfer
2
roller.
[0 to 20 / 4 / 1 A]
Developer Initialization
Initializes the developer and resets the TD and ID sensor outputs to their defaults. Do
2801
this SP after you fill the PCU with developer at machine installation and every time
developer is replaced.
System SP Tables-2