4. Replacement and Adjustment
• Use an S5S test chart to perform the following adjustments.
Registration: Platen Mode
4
A: Leading Edge Registration
B: Side-to-side Registration
1. Place the test chart on the exposure glass and make a copy from one of the feed stations.
2. Check the leading edge and side-to-side registration, and adjust them using the following SP
modes if necessary.
Leading Edge
Side-to-side
Magnification
• Use an S5S test chart to do the following adjustment.
276
SP mode
SP4-010
SP4-011