4. Replacement and Adjustment
A: Leading Edge Registration (3 ± 2 mm)
B: Side-to-side Registration (2 ± 1.5 mm)
1. Check the leading edge registration [A] for each paper feed station, and adjust them using
SP1-001.
Tray: Plain
Tray: Thick 1
Tray: Thick 2
4
By-pass: Plain
By-pass: Thick 1
By-pass: Thick 2
Duplex: Plain
Duplex: Thick 1
2. Check the side-to-side registration [B] for each paper feed station, and adjust them using SP1-002.
By-pass
Tray 1
Tray 2
Tray 3 (Optional PFU tray 1 or LCT)
Tray 4 (Optional PFU tray 2)
Duplex (side 1)
Blank Margin
• If the leading edge/side-to-side registration cannot be adjusted within the specifications, adjust the
leading/left side edge blank margin.
272
Tray
Tray
SP mode
SP1-001-002
SP1-001-003
SP1-001-004
SP1-001-007
SP1-001-008
SP1-001-009
SP1-001-013
SP1-001-014
SP mode
SP1-002-001
SP1-002-002
SP1-002-003
SP1-002-004
SP1-002-005
SP1-002-006