4. Appendix: Service Program Mode Tables
AGC Execution
4603
Executes the AGC.
1 HP Detection Enable
2 HP Detection Disable
FGATE Open/Close
Opens or closes the FGATE signal. This SP automatically returns to the default status
(close) after exiting this SP.
4
[0 or 1 / 0 / 1 / step]
0: OFF, 1: ON
4604
Note:
Gray Balance Set: R
4609*
Adjusts the gray balance of the red signal for each scanning mode.
1 Book Scan
2 DF Scan
Gray Balance Set: G
4610
Adjusts the gray balance of the green signal for each scanning mode.
1 Book Scan
2 DF Scan
Gray Balance Set: B
4611*
Adjusts the gray balance of the blue signal for each scanning mode.
166
• When the registration sensor goes ON, the BCU generates the FGATE signal and
sends it to the LD units.
• As soon as the LD units receive the FGATE signal, they send a feedback signal to
the BCU.
• SC230, SC231 if the FGATE signal fails to switch on or off.
[-384 to 255 / -46 / 1 digit ]
[-384 to 255 / -20 / 1 digit ]