2. A colon is inserted as a delimiter every 4th hexadecimal character.
fe80:0000:0000:0000:0207:40ff:0000:340e
3. The notations can be abbreviated by eliminating zeros where the MSB and digits following the
MSB are zero. The example in "2" above, then, becomes:
fe80:0:0:0207:40ff:0:340e
4. Sections where only zeros exist can be abbreviated with double colons (::). This abbreviation can
be done also where succeeding sections contain only zeros (but this can be done only at one point
in the address). The example in "2" and "3" above then becomes:
fe80::207:40ff:0:340e (only the first null sets zero digits are abbreviated as "::")
-or-
fe80:0:0:0:207:40ff::340e (only the last null set before "340e" is abbreviated as "::")
IPv6 Stateless Auto Setting
Enables/disables the stateless automatic setting for Ethernet/wireless LAN operation.
161*
[0 or 1 / 1 / 1]
1: Enable
0: Disable
Web Item Invisible
Determines whether each item can be set in Websys.
[0x0000 to 0xffff/0xffff]
236*
0: Not displayed, 1: Displayed
Bit 0: NetRICOH
Bit 1: Vendor for consumables
Bit 2-15: Reserved
Web Shopping Link Invisible
Determines whether the NetRICOH link is displayed on the Websys top page and link
page.
237*
[0 or 1 / 1 / 1]
1: Display
0: No display