Touch Screen Calibration - Ricoh OR-C1 Field Service Manual

Table of Contents

Advertisement

4. Replacement and Adjustment
• Make a temporary test chart as shown above using A3/DLT paper.
1. Place the temporary test chart on the ADF and make a copy from one of the feed stations.
2. Check the registration, and adjust using the following SP modes if necessary.
Side-to Side: Front
Side-to Side: Rear
Leading Edge
4
Buckle: Duplex front
Buckle: Duplex rear
Rear Edge Erase
Sub Scan Magnification
• Make a temporary test chart as shown above using A3/DLT paper.
1. Place the temporary test chart on the ADF and make a copy from one of the feed stations.
2. Check the magnification, and adjust using the following SP modes if necessary. The specification is
±1%.
Sub scan magnification

Touch Screen Calibration

After clearing the memory, or if the touch panel detection function is not working correctly, follow this
procedure to calibrate the touch screen.
• Do not attempt to use items [2] to [9] on the Self-Diagnostic Menu. These items are for design use
only.
1. Press
, input 1993 at the ten-key pad, and then press
menu.
278
SP mode
SP6-006-001
SP6-006-002
SP6-006-003
SP6-006-005
SP6-006-006
SP6-006-007
SP mode
SP6-017-001
5 times to open the Self-Diagnostics