No.
Type
• Loose connection
-
-
• Defective HDD
• Defective controller
1. Check that the HDD is correctly connected to the controller.
-
-
2. Replace the HDD.
3. Replace the controller.
No.
Type
Self-diagnostic error: NIB
823
B
[XXXX]: Detailed error code
MAC address check sum error
[6101]
The result of the MAC address check sum does not match the check sum stored in
ROM.
PHY IC error
[6104]
The PHY IC on the controller cannot be correctly recognized.
PHY IC loop-back error
[6105]
An error occurred during the loop-back test for the PHY IC on the controller.
-
Replace the controller.
No.
Type
Self-diagnosis error: Standard NVRAM
824
C
The controller cannot recognize the standard NVRAM installed or detects that the
NVRAM is defective.
• Loose connection
• Defective standard NVRAM
• Defective controller
[1401]
1. Check the standard NVRAM is firmly inserted into the socket.
2. Replace the NVRAM.
3. Replace the controller
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)