1 Warming-up
2 Print
3 Wait
1112*
Image Proc. Temp. Correction
1 Temp.:Normal:Level1
2 Temp.:Normal:Level2
CPM Down Setting
1124*
Specifies the settings for the CPM down mode.
6 High:1st CPM
7 High:2nd CPM
8 High:3rd CPM
9 High:1st CPM Down Temp.:A3
Adjusts the fusing temperature control cycle when the
machine is warming up.
[100 to 2000 / 1000 / 100 msec]
Adjusts the fusing temperature control cycle when the
machine is printing.
[100 to 2000 / 1000 / 100 msec]
Adjusts the fusing temperature control cycle [100 to
2000 / 1000 (North America, Taiwan), 2000 (Other
countries) / 100 msec]
Specifies the correction temperature for the level
1 of the job image control.
[–25 to 10 / 0 / 1 deg]
Specifies the correction temperature for the level
2 of the job image control.
[–25 to 10 / –5 / 1 deg]
Specifies the 1st CPM down ratio against the
normal CPM in the high temperature condition.
[10 to 100 / 60 / 5 %/step]
Specifies the 2nd CPM down ratio against the
normal CPM in the high temperature condition.
[10 to 100 / 50 / 5 %/step]
Specifies the 3rd CPM down ratio against the
normal CPM in the high temperature condition.
[10 to 100 / 25 / 5 %/step]
Specifies the heating roller temperature for 1st
CPM down of A3 paper size.
[100 to 250 / 215 / 1 deg/step]