Interval
This SP sets the page interval for transfer roller cleaning when SP2996 001 is set to "1"
(Yes). Increase this setting only when absolutely necessary. A higher setting increases
wear on the PCU.
2
[0to100/50/1 sheets]
Note: This SP does not execute for the first copy after power on or when the machine
returns from the energy save or auto off mode.
This SP setting does cannot correct poor copies if there is a problem with the TD sensor.
2998*
PCU Reverse Rotation Time
Wait Time
Adjusts the waiting time for starting to rotate the drum in reverse after the end of each
job. The wait time calculation formula is as follows.
1
[0 to 999 / 300 / 1]
This SP is adjusted in units of 30 ms (1 step = 30 ms, 2 steps = 60 ms, etc.)
If "0" is selected, the drum reverses immediately at the end of the job.
Reverse Time
Adjusts the drum reverse rotation time.
2
[0 to 99 / 60 / 1]
This SP is adjusted in units of 60 ms (1 step = 6 ms, 2 steps = 12 ms, etc.)
If "0" is selected, the drum does not reverse at the end of the job.
Brake Time
Adjusts the length of time of braking to stop reverse rotation of the drum.: DFU
3
[0 to 99/0/1]
This SP is adjusted in units of 6 ms (1 step = 6 ms, 2 steps = 12 ms, etc.)
If "0" is selected, the drum stops reverse rotation immediately.
System SP Tables-2
4
155