Ricoh OR-C1 Field Service Manual page 527

Table of Contents

Advertisement

Scan Adjust Error
4645
Displays the error value of the white level or black level adjustment.
1 White Level
2 Black Level
SBU Error
4647
Displays the result of the SBU connection check.
Black Level Adj. Display
4654*
RE: Red Even signal, RO: Red Odd signal
Last Correct Value: RE
1
Color
Last Correct Value: RO
2
Color
Black Level Adj. Display
4655*
GE: Green Even signal, GO: Green Odd signal
Last Correct Value: GE
1
Color
Last Correct Value: GO
2
Color
Black Level Adj. Display
4656*
BE: Blue Even signal, BO: Blue Odd signal
Last Correct Value: BE
1
Color
[0 to 65535 / 0 / 1 digit ]
Displays the previous black offset value for the even red
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
Displays the previous black offset value for the odd red
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
Displays the previous black offset value for the even green
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
Displays the previous black offset value for the odd green
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
Displays the previous black offset value for the even blue
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
System SP Tables-4
4
169