Ricoh OR-C1 Field Service Manual page 528

Table of Contents

Advertisement

4. Appendix: Service Program Mode Tables
Last Correct Value: BO
2
Color
Analog Gain Adjust Last Correct Value: R Color
4658*
Displays the previous gain value of the amplifiers on the controller for Red.
[0 to 7 / 0 / 1 digit/step]
Analog Gain Adjust Last Correct Value: G Color
4
4659*
Displays the previous gain value of the amplifiers on the controller for Green.
[0 to 7 / 0 / 1 digit/step]
Analog Gain Adjust Last Correct Value: B Color
4660*
Displays the previous gain value of the amplifiers on the controller for Blue.
[0 to 7 / 0 / 1 digit/step]
Digital Gain Adjust
4661*
RE: Red Even signal, RO: Red Odd signal
Last Correct Value: RE
1
Color
Last Correct Value: RO
2
Color
Digital Gain Adjust
4662*
GE: Green Even signal, GO: Green Odd signal
Last Correct Value: GE
1
Color
170
Displays the previous black offset value for the odd blue
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
Displays the previous 2nd black offset value for the even
red signal in the CCD circuit board.
[0 to 1023 / 0 / 1 digit/step]
Displays the previous 2nd black offset value for the odd
red signal in the CCD circuit board.
[0 to 1023 / 0 / 1 digit/step]
Displays the previous 2nd black offset value for the even
green signal in the CCD circuit board.
[0 to 1023 / 0 / 1 digit/step]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D120D139D140D141D121D122

Table of Contents