No.
Type
Transfer roller leak error 2
A transfer roller current leak signal is detected. The current feedback signal for the
transfer roller is not detected within the correct time.
• Transfer roller set incorrectly or damaged
• High voltage supply board set incorrectly or defective
402
D
1. Check the high voltage supply board is set correctly.
2. Check the harness of the high voltage supply board.
3. Replace the high voltage supply board.
4. Check the transfer roller is set correctly.
5. Replace the transfer roller.
No.
Type
Separation bias leak error
A separation bias leak signal was detected.
• High voltage supply board defective
411
D
• Discharge plate defective
1. Check the harness of the high voltage supply board.
2. Replace the high voltage supply board.
3. Replace the discharge plate.
No.
Type
Toner supply motor leak error r
More than 1 ampere supplied to the toner supply motor for longer than 200 ms.
490
D
• Toner supply motor defective
1. Replace the toner transport motor.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Service Call Conditions
3
57