4. Appendix: Service Program Mode Tables
32 Down Temp:No. of Page
33 Copy Down Temp
4
34 Copy Down Temp:Center
35 Copy Down Temp:Ends
36 Copy Down Temp:Add:Center
37 Copy Down Temp:Add:Ends
38 Feed Permit Setting:Thick
1106
Fusing Temperature Display
1 Roller Center
2 Roller Ends
3 In the Machine at Power On
1108*
Fusing Soft Start Setting
130
When the fusing temperature at the center of the
hot roller is lowered due to consecutive printing,
the lowered temperature is kept until the number
of sheets set here is printed.
[0 to 20 / 5 / 1 sheet]
When the fusing temperature at both ends of the
hot roller is lowered due to consecutive printing,
the lowered temperature is kept until the number
of sheets set here are printed.
[0 to 20 / 5 / 1 sheet]
Adjusts the subtract temperature for the center
and both ends of the hot roller when the
machine lowers the temperature due to
consecutive printing.
[0 to 30 / 1 / 1 deg]
Adjusts the additional temperature until a
specified period of time passes or a specified
number of sheets are printed after reload.
[0 to 30 / 5 / 1 deg]
Adjusts the temperature at which feeding thick
paper is permitted. Thick paper can be fed
when the specified fusing temperature minus the
actual temperature is the same as or smaller
than this setting.
[0 to 60 / 20 / 1 deg]
Displays the fusing temperature for the center or both
ends of the hot roller.
Displays the temperature in the machine at power on.
This temperature is monitored by the thermistor on the
BCU board.