Power Off - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB CLI (Command Line Interface) Operations
2.2 Setting Commands

2.2.6 power off

Turn off the power of entire system or specified partition.
When the partition which is specified by parameter is not configured, ignore such partition.
When the specified partition is already in power off state, any process will not be executed for that partition.
Only the partitions which are targeted for management can be operated for Partition Operator.
Error message displays when the parameter having partitions which are not targeted for management is
specified. Specified partition cannot be operated.
Privilege: Administrator, Operator, Partition Operator (Partitions targeted for
management only)
(1)
Input format
power off {partition} [all/ <partition#> [ , / -] <partition#>] {force}
(2)
Option
Partition: Shutdown the operating system of partition by which partition number is specified and turns off the
power of partition. This parameter is optional.
The default parameter is processed as the specified partition parameter. Therefore, it is
necessary to specify the partition.
Partitions are specified as follows.
force: Shows that the power of the partition turns off forcefully without shutting down the operating system
of partition.
(3)
Usage example
None
(4)
Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (CA92344-0540).
The specified parameter is invalid.
The specified partition number is invalid.
Unable to execute this command because the system is under maintenance.
Unable to execute this command because the Partition#x is under maintenance.
Unable to power off the partition#%d.
Unable to force power off on the partition#%d.
Command Failed. Code=0x%04X, 0x%02X
Unable to power off the Partition#n because you have not authority to operate this partition.
Unable to execute this command on a standby MMB.
Unable to power off the partition(s) because the partition which does not have authority to you is included in
the specified parameter.
Unable to execute power control because the firmware is updating.
all (All defined partitions) specified
Specifies Partition numbers by delimiting with comma
Specifies with the range of partition number
364
CA92344-0539-04

Advertisement

Table of Contents
loading

Table of Contents