Permission Required For Collaboration Program - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

Dynamic Reconfiguration Operation
5.2 Hot plug collaboration function

5.2.7 Permission required for collaboration program

P command is executed with the root permission. And because hot plug collaboration function is executed
as one function of the DR command, the collaboration programs must be assigned the execution attribute of
the root permission. Collaboration programs without the execution attribute of the root permission are not
executed.
5.2.8 Argument passed to collaboration program
When executing a collaboration program, hot plug collaboration function passed hot plug event timing to the
collaboration program as option. Result of hot plug and hot added/removed resources are passed to the
collaboration program as option, when the collaboration program is executed at the addition/deletion of
SB/IOU failure time.
The list of the arguments passed to a collaboration program is shown below.
O
Options
-
p
-
e
-
r
-
v
-
c
Arguments
hot plugged device
SBx
IOUy
hot plug eventl timing
ADD_PRE
ADD_POST
RM_PRE
RM_POST
result of hot plug
SUCCESS
FAILURE
none
CPU number
Specifies the hot plugged device.
"x" and "y" are set to either -1 or 0-3.
Specifies the hot plug event timing.
ADD_PRE : before dynamic addition
ADD_POST : after dynamic addition
RM_PRE: before dynamic deletion
RM_POST : after dynamic deletion
Specifies the result of hot plug
When the hot plug event timing is only ADD_POST or
RM_POST, this option is specified.
Specifies the verbose mode.
Collaboration program can use it for trigger of debug messages.
Specifies the hot added/removed CPU number list from now.
When hot plugged device is SBx and hot plug event timing is
ADD_PRE or RM_PRE, this option is specified.
Example of specified CPU number list is shown below. The CPU
number list is a list delimited by the comma. When this list is
delimited by the hyphen, it means all ranges of the first and last
number are included. None means there is no CPU.
1-10
2,3
1-10,12-19
None