Fujitsu PRIMEQUEST 2000 Series Tool Reference page 144

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Web-UI (Web User Interface) Operations
1.2 [System] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E
Items
Status
Vendor
Model
Capacity
Temperature
Logical Drives
Sensor#
Status
Raid Level
Physical Drives
assignment
Missing drives count
RAID Action Progress
Drive Type
Slot#/Sensor#
Action
Progress(%)
Estimated time
remaining (hh:mm:ss)
Expander
Expander#
Status
PSU
#
PSU
The state of a physical drive is displayed.
·
Operational
·
Available
·
Failed
·
Hot Spare
·
Rebuilding
·
SMART err
·
Shielded
·
Bad Block
·
Not-present
The vendor name of a physical drive is displayed.
The model name of a physical drive is displayed.
The capacity of a physical drive is displayed.
The temperature of a physical drive is displayed.
The sensor number of a logical drive is displayed.
The state of a logical drive is displayed.
The RAID level of a logical drive is displayed.
The slot number of a physical drive that composes a logical drive is displayed.
The number of physical drives missed to compose a logical drive at the RAID level
is displayed.
The drive type that the RAID action is executed is displayed.
·
Physical : Hardware RAID
·
Logical : Software RAID
Slot# from which the RAID action is executed is shown when Drive Type is
Physical, and Sensor# from which the RAID action is executed is shown when
Drive Type is Logical.
The RAID action under execution is displayed.
·
Rebuilding : It is shown for a physical drive to execute the rebuild of the RAID
drive.
·
Copyback Running : It is shown for a physical drive to execute the copy
backing
·
MDC Running : It is shown for a logical drive to execute MDC(Make Data
Consistent).
The progress rate of the RAID action under execution is displayed by the
percentage.
The remainder time that will be expected by the time the RAID action under
execution is completed is displayed.
The number of the expander is displayed.
Displays the status of the Expander.
OK
Warning
Failed
Not-Present
The number of the exp PSU ander is displayed.
143
Description
CA92344-0539-04

Advertisement

Table of Contents
loading