Fujitsu PRIMEQUEST 2000 Series Configuration Manual

Fujitsu PRIMEQUEST 2000 Series Configuration Manual

Hide thumbs Also See for PRIMEQUEST 2000 Series:

Advertisement

PRIMEQUEST 2000 Series
Converged Network Adapter
FCoE Boot Configuration Manual
Copyright 2016 FUJITSU LIMITED
CA92344-0966-01

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMEQUEST 2000 Series

  • Page 1 PRIMEQUEST 2000 Series Converged Network Adapter FCoE Boot Configuration Manual Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 2: Introduction

    Unless adopting measures for ensuring safety, do not use this product in such high-safety applications. When you use this product in high-safety applications, before use, consult with our sales representatives. Storage of Attached Articles Since attached articles are needed to operate server with, keep it in a safe place. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 3 In this manual, procedure of consecutive operations are represented as follow by connecting them with "→". Ex: Click 「Start」button, then, point 「All Programs」, and then, click 「Accessories」 ↓ 「Start」button → 「All Programs」→「Accessories」 Click on this order. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 4 Converged Network Adapter CNA、This Product Internet Small Computer System Interface iSCSI Fibre Channel over Ethernet FCoE Storage Area Network World Wide Name ServerView Installation Manager SVIM ServerView Suite Preboot eXecution Environment Unified Extensible Firmware Interface UEFI, uEFI Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 5: Table Of Contents

    5.1.2. Changing Setting of PCI ROM Priority ....................29 5.2. Setting in Device Manager ........................33 5.3. Settings of Boot of Converged Network Adapter ................34 5.3.1. Additional Settings of Boot Device ....................... 36 6. OS Installing ......................... 41 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 6: Fcoe Boot Configuration

    You can add built-in disk to your server to reduce I/O load. 2) Download the latest version of driver and firmware of Converged Network Adapter from the following URL and use them. http://support.ts.fujitsu.com/download/Index.asp Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 7: Steps Of Configuring Fcoe Boot

    2. Steps of Configuring FCoE Boot We explain the steps of configuring FCoE Boot. In this document, we explain the steps to build FCoE Boot Environment on PRIMEQUEST 2000 series. For information for setting and adjustment procedure of FCoE storage device and Converged Fabric Switch, refer to the manuals accompanying to each product.
  • Page 8 FCoE port enabled(linked) and boot from the port in Rescue Mode. Setting of Connection of ETERNUS For more information about configuration which is required to connect ETERNUS, refer to the following Web site. http://storage-system.fujitsu.com/jp/catalog/manual.html Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 9: Setting Of Pxe Boot Parameters

    During the system is starting up, if prompt of PXESelect Utility is displayed as shown below, then press <Ctrl> + <P> key. Figure 3-1 As Controller Configuration screen is displayed, set MultiChannel to DISABLED. Figure 3-2 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 10 Next, set Personality of CNA controller to "FCoE." Figure 3-3 To save the settings, press <F7> key. If the screen as shown below is displayed, press <Y> key. Figure 3-4 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 11 If the settings are saved, press [Esc] key to return to the previous screen. Figure 3-5 As you return to the front screen shown in Figure 3-2, press [Esc] key to terminate PXESelect Utility. After that, the server restarts. Figure 3-6 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 12 BIOS startup screen. Make sure that a message "Link Up: Physical Link Established" as shown below is displayed. Figure 3-7 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 13: Configuring Fcoe Boot (Legacy Mode)

    <Alt E> key or <Ctrl E> key immediately(Less than 5 seconds). Figure 4-1 List of adapters(controllers) which are mounted in the server is displayed as shown below, and then, select subject adapter(controller), and press <Enter> key. Figure 4-2 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 14: Enabling Of Boot Bios Of Cna

    4.2. Enabling of Boot BIOS of CNA To enable FCoE Boot of the CNA, select [Enable/Disable Boot from SAN] in main menu of Emulex OneConnect FCoE BIOS Utility screen, and press <Enter> key. Figure 4-4 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 15 The default value for the Boot BIOS is “Disable”. Figure 4-5 To use FCoE Boot function, enable Boot BIOS of at least one CNA. If you enabled the Boot BIOS, status of Boot BIOS changes as shown below (red line part). Figure 4-6 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 16: Scanning Of Target Device

    Scanning of the target devices is performed, a list of the target devices is displayed as shown in the figure below. In this screen, only the target device which is detected is displayed. Figure 4-8 Make sure that WWN and LUN of the target storage is displayed correctly. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 17: Configuring Of Boot Device

    If the system hit a hardware error and failed to boot the first entry, it boots from the next bootable entry. Select a boot entry, and press <Enter> key. Figure 4-10 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 18 Pull-down menu is displayed as shown in the figure below. There is a need to enter LUN in the form. Using up-arrow or down-arrow, enter the LUN in hexadecimal format, and press <Enter>. LUN can be from 0 to 255. Figure 4-12 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 19 Using up-arrow or down-arrow, select a way to boot. If you select WWPN, The WWPN entry you select is saved in flash memory. If you select DID, The DID entry you select is saved in flash memory. Press <Enter> key. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 20 Press <Esc> key to return to the previous screen. In the screen, the status of target device is changed to the "Used". Make sure that the status of target device is "Used". Figure 4-15 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 21: Advanced Setting Of Adapter's Parameters

    4.5. Advanced Setting of Adapter’s Parameters To set detailed parameters of the adapter, in main menu of BIOS Utility, select "Configure Advanced Adapter Parameters" as shown below figure and press <Enter> key. Figure 4-16 Figure 4-17 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 22: Changing Default Alpa (Arbitrated Loop Physical Address)

    4.5.1. Changing Default ALPA (Arbitrated Loop Physical Address) Important This option is applied to Arbitrated Loop (FC-AL) connection. FCoE protocol does not support FC_AL connection. So, this parameter is not needed to set. Figure 4-18 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 23: Changing Plogi Retry Timer

    When port resumes operating, it scans the loop to detect device. PLOGI (Port Login) Retry Timer is time one PLOGI takes to scan entire of the loop. (Default value is 0 msec.) Figure 4-19 4.5.3. Enable or Disable Spinup Delay This option allows to enable or disable the Disk Spin-up Delay. Figure 4-20 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 24: Auto Scan Setting

    This option, in order to issue query to the name server, allows to enable Auto Scan of LUN device and to enable the first device in the boot entry list. Select "Auto Scan Setting", and press <Enter> key. Figure 4-21 Auto Scan Setting menu is displayed. Figure 4-22 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 25: To Take Effect Of Settings

    A message as below in the figure displays, enter <Y> to reboot the system. So the settings you have done are taken effect to the system. Figure 4-24 If you have done till "4.5.5. To Take Effect of Settings", go to "6. OS Installing". Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 26: Configuring Fcoe Boot In Uefi

    5.1. Startup Converged Network Adapter in UEFI mode To install OS in UEFI mode, startup converged network adapter in UEFI mode. During the server starts up, if screen as shown below is displayed, press <F1> key immediately. Figure 5-1 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 27: Changing Boot Mode

    UEFI menu as shown below in the figure is displayed. Select [Boot Maintenance Manager], and press <Enter> key. Figure 5-2 5.1.1. Changing Boot Mode In Boot Maintenance Manager、select [Boot Mode], and press <Enter> key. Figure 5-3 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 28 As Boot Mode screen is displayed, move cursor onto < UEFI and Legacy>, and press <Enter> key. Figure 5-4 When a menu like the following picture is displayed, select [Only UEFI], and press <Enter> key. Figure 5-5 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 29: Changing Setting Of Pci Rom Priority

    Figure 5-6 5.1.2. Changing Setting of PCI ROM Priority Pressing <ESC> key in Boot Maintenance Manager screen, return to main menu (Figure 5-2), and move cursor onto [Device Manager], and press <Enter> key. Figure 5-7 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 30 As Device Manager screen is displayed, move cursor onto [PCI Subsystem Configuration], press <Enter> key. Figure 5-8 As PCI Subsystem Configuration screen is displayed, move cursor onto <Legacy ROM> at PCI ROM Priority, and press <Enter> key. Figure 5-9 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 31 As pull-down menu is displayed as shown in the figure below, move cursor onto [EFI Compatible ROM], press <Enter> key. Figure 5-10 To commit the settings, move cursor onto [Commit Changes and Exit], and press <Enter> key. Figure 5-11 If you have completed the settings described till here, restart the system. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 32 We shows an example of a procedure to restart the system. In main menu, move cursor onto [Boot Maintenance Manager], and press <Enter> key. Figure 5-12 In Boot Maintenance Manager menu, move cursor onto [Reset System], and press <Enter> key to restart the system. Figure 5-13 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 33: Setting In Device Manager

    If the settings has been set correctly, in Devices List of Device Manager screen, the Converged Network Adapters (e.g. “Emulex OCe14102-U 10Gb CNA – FCoE”) are displayed by the amount of the number of ports. Figure 5-15 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 34: Settings Of Boot Of Converged Network Adapter

    Select the Converged Network Adapter (e.g. Emulex OCe14102-U 10Gb CNA - FCoE), and press <Enter> key. Figure 5-16 As shown in the figure below, move cursor onto the value of Set Boot from SAN, and press <Enter> key. Figure 5-17 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 35 Select "Enable" from the pull-down menu, and press <Enter> key. Figure 5-18 Make sure that the value of Set Boot from SAN has been changed to <Enable>. Figure 5-19 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 36: Additional Settings Of Boot Device

    Menu] and press <Enter> key to return to previous screen. If you cannot find your target boot device in the list, check if converged fabric switch and FCoE storage are correctly set and the cables are correctly connected. Figure 5-21 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 37 Move cursor onto [Add Boot Device] and press <Enter> key to make the setting of the Boot Device. Figure 5-22 Select the target boot device as shown in the figure below, and press <Enter> key. Figure 5-23 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 38 Since the LUNs of the target boot device are listed, select one to boot, and press <Enter> key. Figure 5-24 To save the settings, move cursor onto [Commit Change] and press <Enter> key. Figure 5-25 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 39 To exit the target converged network adapter screen (Emulex OCe14102-U 10Gb CNA - FCoE), press <Esc> key. If a message prompts to save the settings is displayed, press <Y> key to save the settings. Figure 5-26 Press <Esc> key to exit Device Manager screen. Figure 5-27 Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 40 Figure 5-27 In Boot Maintenance Manager screen, select [Reset System] and press <Enter> key to reboot the system. Figure 5-28 If you have done “Additional Settings of Boot Device", go to "OS Installing" in Chapter 6. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 41: Os Installing

    Then select [EFI Internal Shell] and press <Enter> key to launch EFI shell. If you see "blk0: BlockDevice" as shown in the figure below, the settings are completed. Figure 6-2 Using SVIM (SeverView Install Manager), install OS of purpose. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 42 Depending on storage device, there is a case that the settings of parameters of CNA driver are required. For more information on the storage device, refer to the manual of the storage device. For more information on the settings of connection to ETERNUS, refer to the manual of ETERNUS. Copyright 2016 FUJITSU LIMITED CA92344-0966-01...
  • Page 43 PRIMEQUEST 2000 Series Converged Network Adapter FCoE Boot Configuration Manual CA92344-0966-01 February 2016 Published by Fujitsu Limited The contents of this document may be changed without a notice for the improvement. ● Our company does not assume responsibility for infringements of patent rights or other rights of ●...

Table of Contents