Show Raid Bbu - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB CLI (Command Line Interface) Operations
2.3 Commands for Display

2.3.52 show raid bbu

Displays FBU information attached to the specified RAID adapter.
Privilege: All
(1)
Input format
show raid bbu [SB | DU | IOU | PCI_BOX] <UNIT#>-<PCISLOT#>
(2)
Option
None
(3)
Usage example
Example: When you display FBU information on SB#0.
# show raid bbu SB 0-0
Status:
Type:
Vendor:
Manufacturer date:
Intelligent BBU:
Auto learn mode:
Next learn time:
Auto learn period:
Design voltage:
Voltage:
Temperature:
Design capacity:
Remaining capacity:
Capacitance:
(4)
Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (CA92344-0540)..
No logical drive is assigned to the controller.
Too much arguments argc=%d.
Too few arguments argc=%d.
The specified parameter is invalid. %s
The specified controller is not found.
Internal error [%d:%d].
The operation is failed. %s
Unable to execute the command because the %s is under maintenance.
Normal
FBU
LSI
03/21/2012
Yes
Transparent
Thu 17 Jul 2014 01:09:23 PM
28 Days
9.411 V
9.518 V
27 deg C
283 J
321 J
100 %
480
CA92344-0539-04