Snmp V1/V2 Trap Receivers Configuration - Ubiquiti EdgeSwitch ES-24-250W Administration Manual

User interface for poe switches
Hide thumbs Also See for EdgeSwitch ES-24-250W:
Table of Contents

Advertisement

EdgeSwitch
Administration Guide

SNMP v1/v2 Trap Receivers Configuration

Use the SNMP v1/v2 Trap Receivers configuration page to configure settings for each SNMPv1 or SNMPv2
management host that will receive notifications about traps generated by the device. The SNMP
management host is also known as the SNMP trap receiver.
To access the page, click System > Advanced Configuration > SNMP > Trap Receiver V1/V2 from the
navigation menu.
Field
Host IP Address
Community Name
Notify Type
SNMP Version
Timeout Value
Retries
Filter
UDP Port
Use the buttons to perform the following tasks:
• To add an SNMP trap receiver and configure its settings, click Add. In the Add SNMP v1/v 2 Host dialog box,
enter the required information, and then click Submit to apply the changes.
• To delete one or more SNMP trap receivers from the list, select each entry to delete, click Remove, and
confirm the deletion.
• Click Refresh to refresh the page with the most current data from the switch.
To retain the changes across the switch's next power cycle, click System > Configuration Storage > Save.
Ubiquiti Networks, Inc.
SNMP v1/v2 Trap Receivers
SNMP v1/v2 Trap Receivers Fields
Description
The IP address of the SNMP management host that will receive traps generated by the device.
The name of the SNMP community that includes the SNMP management host and the SNMP agent on
the device.
The type of SNMP notification to send the SNMP management host:
Inform
An SNMP message that notifies the host when a certain event has occurred on the device.
The message is acknowledged by the SNMP management host. This type of notification is not
available for SNMPv1.
Trap
An SNMP message that notifies the host when a certain event has occurred on the device.
The message is not acknowledged by the SNMP management host.
The version of SNMP to use, which is either SNMPv1 or SNMPv2.
The number of seconds to wait for an acknowledgment from the SNMP management host before
resending an inform message.
The number of times to resend an inform message that is not acknowledged by the SNMP
management host.
The name of the filter for the SNMP management host. The filter is configured by using the CLI and
defines which MIB objects to include or exclude from the view. This field is optional.
The UDP port on the SNMP management host that will receive the SNMP notifications. If no value is
specified when configuring a receiver, the default UDP port value is used.