Time-Based Group Statistics - Ubiquiti EdgeSwitch ES-24-250W Administration Manual

User interface for poe switches
Hide thumbs Also See for EdgeSwitch ES-24-250W:
Table of Contents

Advertisement

EdgeSwitch
Administration Guide
Field
Release Packets Transmitted
Total Packets Transmitted
Use the buttons to perform the following tasks:
• Click Clear Counters to clear all the counters. This resets all statistics for this port to the default values.
• Click Refresh to refresh the data on the screen and display the most current statistics.
To retain the changes across the switch's next power cycle, click System > Configuration Storage > Save.

Time-Based Group Statistics

Use the Time-Based Group Statistics page to define criteria for collecting time-based statistics for interface
traffic. The time-based statistics can be useful for troubleshooting and diagnostics purposes. The statistics
application uses the system clock for time-based reporting, so it is important to configure the system clock
(manually or through SNTP) before using this feature.
To access the page, click System > Statistics > Time Based > Group in the navigation menu.
Field
Group
Time Range
Ubiquiti Networks, Inc.
Network Port DHCPv6 Client Statistics Fields (Continued)
Description
Number of release messages the DHCPv6 client has sent to the server to indicate that it no longer
needs one or more of the assigned addresses.
Total number of messages sent to all DHCPv6 servers.
Time-Based Group Statistics
Time-Based Group Statistics Fields
Description
The type of traffic statistics to collect for the group, which is one of the following:
Received
The number of packets received on the interfaces within the group.
Received Errors
The number of packets received with errors on the interfaces within the group.
Transmitted
The number of packets transmitted by the interfaces within the group.
Received Transmitted
The number of packets received and transmitted by the interfaces within
the group.
Port Utilization
The percentage of total bandwidth used by the port within the specified time
period.
Congestion
The percentage of time within the specified time range that the ports experienced
congestion.
The name of the periodic or absolute time range to use for data collection. The time range is
configured using the Time Range Entry Summary page (see "Time Range Entry Configuration" on
page 111). The time range must be configured on the system before the time-based statistics can be
collected.