Configuring Time Ranges

You can use these pages to configure time ranges to use in time-based access control list (ACL) rules.
Time-based ACLs allow one or more rules within an ACL to be based on a periodic or absolute time. Each ACL
rule within an ACL except for the implicit deny all rule can be configured to be active and operational only
during a specific time period. The time range pages allow you to define specific times of the day and week in
order to implement time-based ACLs. The time range is identified by a name and can then be referenced by
an ACL rule defined with in an ACL.

Time Range Configuration

Use the Time Range Summary page to create a named time range. Each time range can consist of one
absolute time entry and/or one or more periodic time entries.
To access this page, click System > Advanced Configuration > Time Range > Configuration.
Field
Admin Mode
Time Range Name
Time Range Status
Periodic Entry Count
Absolute Entry
Use the buttons to perform the following tasks:
• To add a time range, click Add, enter a name for the time range configuration, and click Submit to create
the time range.
• To delete a configured time range, select each entry to delete, click Remove, and confirm the action.
• If you change the Admin Mode setting on this page, click Submit to apply the change.
• Click Refresh to update the information on the screen.
To retain the changes across the switch's next power cycle, click System > Configuration Storage > Save.
Ubiquiti Networks, Inc.
Time Range Summary
Time Range Summary Fields
Description
Used to Enable or Disable the Time Range administrative mode. When enabled, actions with
subscribed components are performed for existing time range entries.
The unique ID or name that identifies this time range. A time-based ACL rule can reference the name
configured in this field.
Shows whether the time range is Active or Inactive. A time range is Inactive if the current day and time
do not fall within any time range entries configured for the time range.
The number of periodic time range entries currently configured for the time range.
Shows whether an absolute time entry is currently configured for the time range.