Use the System Trap Flags page to enable or disable traps the switch can send to an SNMP manager. When
the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled
SNMP Trap Receivers, and a message is written to the trap log.
To access the page, click System > Advanced Configuration > Trap Manager > Trap Flags page.
The fields available on the System Trap Flags page depends on the packages installed on your system. For
example, if your system does not have the BGP4 package installed, the BGP Traps field is not available. The
illustration above and the table below show the fields that are available on a system with all packages
installed.
Field
Authentication
Link Up/Down
Multiple Users
Spanning Tree
ACL Traps
Power Supply Module State
Temperature
Use the buttons to perform the following tasks:
• If you make any changes to this page, click Submit to apply the changes to the system.
• Click Refresh to refresh the data on the screen with the present state of the data in the switch.
Ubiquiti Networks, Inc.
System Trap Flags
System Trap Flags Fields
Description
When selected, this option enables activation of authentication failure traps by selecting the
corresponding line on the pulldown entry field. This feature is enabled by default.
When selected, this option enables activation of link status traps by selecting the corresponding line
on the pulldown entry field. This feature is enabled by default.
When selected, this option enables activation of multiple user traps by selecting the corresponding
line on the pulldown entry field. This feature is enabled by default. This trap is triggered when the same
user ID is logged into the switch more than once at the same time (either via Telnet or the serial port).
When selected, this option enables activation of spanning tree traps by selecting the corresponding
line on the pulldown entry field. This feature is enabled by default.
When selected, this option enables activation of ACL traps by selecting the corresponding line on the
pulldown entry field. This feature is disabled by default.
When selected, this option enables SNMP notifications when power supply events occur.
When selected, this option enables SNMP notifications when temperature events occur.
Configuring System Information