2-16
System Status
Disabling a device
You can also disable any device connected to the console.
Keypresses
1. Press [•]
2. Press F1 and select the device
3. Press F3 Disable
4. Press [STAGE] or [CLEAR] to return
to the editor.
¾ ¾
Note
When the alphanumeric keyboard is locked it is designated as Disabled in the System
Status window.
If the Submaster Wing is disconnected from the console, the output from the Wing is
moved to the editor and the Status error message blinks in the command line. The
assignments to the Submaster Wing are retained. If you reconnect the Submaster Wing,
the situation is the same as prior to the disconnect. However, if you go to the System
Status window and tell the console to ignore or disable the Submaster Wing, all of the
assignments on the Wing are released.
Sabre
Results/Comments
The System Status window opens. The
peripheral device status is displayed.
Disabled appear in red next to the device.