Print Chart

HeadService
Print Chart
Print Chart
CLEAR to Stop

Actuator Status

HeadService
Actuator Status
Actuators Failed
None
5050/5100 User's Manual
Print a graph of the number of times individual print heads have
been fired.
1. While in the HeadService menu, press the
menu browse key until Print Chart is displayed in the lower right
corner of the LCD.
2. Press the Select key to print the print chart. CLR to Stop will be
displayed in the lower right corner of the LCD.
PRINT CHART SAMPLE
Identify an actuator failure.
1. While in the HeadService menu, press the
menu browse key until Actuator Status is displayed in the lower
right corner of the LCD.
2. Press the Select key to display the failed actuator. If no actuator
has failed, the word None will be displayed in the lower left corner
of the LCD. If there is a failed actuator, the number of the failed
actuator will be displayed in the lower left corner of the LCD.