Replacement Procedure - Genicom 5050 User Manual

Hide thumbs Also See for 5050:
Table of Contents

Advertisement

Replacement Procedure

5050/5100 User's Manual
The actuators for the 500-lpm and 1000-lpm models are physically
marked to distinguish them from lower speed model actuators. The
brazed block on the 500-lpm and 1000-lpm model has a black
connector housing. See Figure 7-3.
BLACK BRAZED BLOCK
(1000-LPM SHOWN)
The handle on the actuator is used to lift the print head from the
printer. During installation, press down and to the right on the
barrels of the print head to position it properly.
Do not operate the printer with a print head removed. All 33
heads must be in place with their connectors secured so that
shuttle balance is maintained.
To remove and replace a print head, complete the following steps:
1. Turn the printer power off and disconnect the power cord from
the AC source.
2. Open the top cover and set the print gap wheel to the LOAD
position.
3. Remove the ribbon cartridge.
4. Tilt the control panel up and towards the front of the printer.
5. Starting with the middle one, unscrew the three captive
thumbscrews and remove the ribbon deck.
If the printer has been printing for an extended time, allow it to
cool for five minutes before replacing print heads.
FIGURE 7-3
Note
Note
162
GEK-99044E

Advertisement

Table of Contents
loading

This manual is also suitable for:

5100

Table of Contents