High Trip Pt%

80
5050/5100 User's Manual
High Trip Pt%
This sub-menu is used to configure a High Trip Point setting for the
serial interface as a percentage of total buffer size. This setting
configures the point where the printer transmits a signal to the host
when the buffer is approaching being full. For example, the default
setting is set to 80. This means the printer will send a full buffer
signal to the host that the buffer has filled to 80% capacity. The 20%
of the buffer acts as a cushion allowing enough time for the printer to
process the data in its buffer while giving the host time to stop
transmitting data before the buffer is completely (100%) full and data
is lost.
1. While in the Serial Setup menu, press the ◄ (left) or ► (right)
menu browse key until High Trip Pt% is displayed in the lower
right corner of the display menu.
2. Press the Select key. High Trip Pt% will be displayed in the upper
left corner of the LCD, and the current setting will be displayed in
the lower right corner of the LCD. Notice the cursor (underline) is
now shown under the first digit and the default number is 80.
The four menu browse keys revert to data entry operation. The
horizontal ◄ ► (left or right) keys position the cursor (underline)
under the digit to be changed; the vertical ▲ ▼ (up or down keys
increment/decrement the selected digit by one.
3. Press the Clear key after all changes are complete and the
desired value is displayed in the lower right corner of the LCD.
Pressing the Clear key does not erase the values entered, but does
allow the user to exit the User Set menu.
Repeat this section if further changes are necessary.
Note
82
GEK-99044E