Malfunction code
2.5
How to reset
• Different malfunction resetting procedures apply depending on the type of the malfunc-
tion code.
* List of Malfunction Resetting Procedures
Resetting Procedure
Press the Trouble Reset Switch
on the Tech. Rep. Setting
Switches Board
Turn OFF and ON the Power
Switch.
Open and close the Front Door
bizhub C350 Field Service Ver. 2.0 April 2004
Applicable Malfunctions
Exposure lamp
Fusing
Scanner
Mechanical control
Scanner
Memory
NIC
Imaging Unit
LPH correction data
Mechanical control
NVRAM initialization
Punch Unit
All but above
4-26
Applicable Malfunction Codes
C04XX
C05XX
C06XX
C3332, 3333
C0650, C0660, C3310, C3700
C12XX
C12D0, C1800
C13D1, C13D2, C13D3, C13D4
C13D5, C13D6, C13D7, C13D8
C3331, C3FXX
C3E00, C3E01, C3E02
C0B7X
All malfunction codes but those
listed above