bizhub C350 Field Service Ver. 2.0 April 2004
4.6.11

Monochrome Image Density

Functions
• To fine-adjust the density of the printed image for a black copy
Use
• To vary the density of the printed image of a black copy
Adjustment
Lighter (2 steps), Std, Darker (2 steps)
Range
Adjustment
If the black is light, touch the Darker key.
Instructions
If the black is dark, touch the Lighter key.
Adjustment
1. Call the Tech. Rep. Mode to the screen.
2. Touch these keys in this order: "Image Adjust" → "Monochrome Image density."
Procedure
3. Touch the Lighter or Darker key as necessary to correct the image density.
4.6.12

Bias Voltage Choice

Functions
• To change the setting of the developing bias voltage
• When this function is turned ON, it decreases the developing bias voltage, thereby
preventing voltage leak from occurring.
Use
• Use when patches of white occur in the image in an ambience of low atmospheric
pressure, such as in high altitudes.
Setting/
• The default setting is OFF.
Procedure
ON
OFF