Periodical check
[4]
bizhub C350 Field Service Ver.1.0 Mar. 2004
3. Remove the Registration Roller
[3]
Cover.
☞ 2-4
4. Clean the Paper Empty Sensor [3]
with a brush or the like.
4582fs2519c0
5. Open the Paper Exit Section Cover.
6. Clean the Paper Exit Sensor [4] with
a brush or the like.
4582fs2520c0
2-6