bizhub C350 Field Service Ver.1.0 Mar. 2004
4.4.5
Manual adjust: CD Image scan position adjustment
Adjusted range: -3 mm to + 3 mm
A. Adjustment procedure
1. Set the mode to the Tech. Rep. Mode.
2. Touch "ADF Check".
3. Touch "Original Stop Position".
[1]
4582fs3516c0
C
D
4582fs3518c0
3-13
Mechanical adjustment
4. Select "Feed Set (Common)".
5. Enter the value from the ten-key pad.
(Press the "ID" key to change the
code.)
• To scan the image in the direction of
C, set the code to -.
• To shift the image in the direction of D,
set the code to +.
6. Touch "END".
4582fs3539e0
Need help?