bizhub C350 Field Service Ver.2.0 April 2004
4.3.32

Scanner Drive Cables

A. Removal Procedure
[2]
[3]
[6]
[7]
1. Remove the Rear Cover.
☞ 2-42
2. Remove the Control Panel.
☞ 2-44
[1]
3. Remove four Presser Bars [1] of Flat
[1]
4036fs2094c0
4. Remove the IR Front Cover.
☞ 2-44
[3]
5. Remove four screws [2] and the con-
4036fs2095c1
6. Remove the Original Glass.
☞ 2-44
7. Remove the Scanner Assy.
[3]
☞ 2-68
8. Unhook the springs [3] of the Scan-
4036fs2547c0
[5]
9. Remove the Scanner Motor Assy.
[4]
☞ 2-66
10. Remove the screw [4] and then slide
4036fs2548c0
11. Remove the Screw [6], and slide the
4036fs2549c0
2-69
Cable.
trol panel base [3].
ner Drive Cables on the hook side,
one each at the front and in the rear.
the front pulley [5] toward the front.
Wire Pulley [7] (Rear side) in the
direction of front side.