bizhub C350 Field Service Ver.1.0 Mar. 2004
1.1.6
Exit Roller / Roll
[3]
[2]
1.1.7
Turnover Roller
[2]
1.1.8
Sensor Section
[2]
A. Cleaning procedure
1. Open the Paper Exit Section Cover
[1]
2. Wet a cloth with alcohol, and use it to
4582fs2515c0
A. Cleaning procedure
1. Open the Paper Exit Section Cover
[1]
4582fs2516c0
2. Wet a cloth with alcohol, and use it to
[3]
4582fs2517c0
A. Cleaning procedure
[1]
1. Remove the Registration/Timing
☞ 2-4
2. Clean the Registration [1]/Timing
4582fs2522c0
2-5
Periodical check
[1].
wipe up the Exit Roller [2]/Roll [3].
[1], and open the Turnover Guide
Plate [2].
wipe up the Turnover Roller [3].
Sensor mounting plate.
Sensor [2] with a blower brush or the
like.