I/O check
3.
I/O check
3.1
Check procedure
• To allow sensors to be checked for operation easily and safely, data applied to the IC on
the board can be checked on the panel with the main unit in the standby state (including
a misfeed, malfunction, and closure failure condition).
<Procedure>
1. Set the mode to the Tech. Rep. Mode.
2. Touch the "ADF Check" key.
3. Touch the "I/O Check" key.
4. Operate the sensor to check by using paper or the like, and check the screen display.
(Paper detected: 1, No paper detected: 0)
3.2
I/O check list
3.2.1
I/O check screen
• This is only typical screen which may be different from what are shown on each individ-
ual main unit.
• Note with care that the Take-up (Feed) Section Open / Close Sensor, the Transport (Con-
vey) Section Open / Close Sensor, the Exit Section Open / Close Sensor and the Middle
Tray Open / Close Sensor are displayed as Faulty Set Detected when they are opened.
The "Convey S" on the IR. The ADF up to 15 degree open when sensor
(PC202)detected.
<Output display of Width S>
• The operation of the sensor can be checked whether it is normal or faulty by changing
the guide width of the Document Take-up Tray to change the output value.
bizhub C350 Field Service Ver.1.0 Mar. 2004
3-4
4582fs3529e0