Malfunction code
2.6.9
C0040: Suction Fan Motor's failure to turn
Suction Fan Motor (M12)
Step
Check the connector of motor for proper connection
1
and correct as necessary.
Check the fan for possible overload and correct as
2
necessary.
M12 operation check
3
4
Change PWB-MC
2.6.10
C0046: Fusing Cooling Fan Motor /1's failure to turn
Fusing Cooling Fan Motor/1 (M9)
Step
Check the connector of motor for proper connec-
1
tion and correct as necessary.
Check the fan for possible overload and correct as
2
necessary.
3
M9 operation check
4
Change PU-1
bizhub C350 Field Service Ver. 2.0 April 2004
Relevant Electrical Parts
Control Board (PWB-MC)
Action
Relevant Electrical Parts
DC Power Supply (PU1)
Action
4-30
WIRING DIAGRAM
Control Signal
—
—
PWB-MC PJ18MC-9 (LOCK)
PWB-MC PJ18MC-7 (REM)
—
WIRING DIAGRAM
Control Signal
—
—
PU1 PJ17PU1-5 (LOCK)
—
Location
(Electrical
Component)
—
—
6-P
—
Location
(Electrical
Component)
—
—
2-K
—