TECH. REP. MODE
4.8.8
Server set (KRDS) / Server set (RD)
A. Server for RX
• These are the settings for the RX server used in the Remote Diagnosis System for the
standard controller.
(1) POP3 server
Functions
• To set the POP3 server address used for the Remote Diagnosis System for the
standard controller.
Use
• To set the address of the POP3 Server
Setting/Procedure • IP Address Version 4 format
[0 to 255]. [0 to 255]. [0 to 255]. [0 to 255]
(2) POP3 login name
Functions
• To set the logon name for the POP3 server used for the Remote Diagnosis Sys-
tem for the standard controller.
Use
• To set the logon name for the POP3 server
Setting/Procedure • The default setting is No.
• Up to 64 characters (alphanumeric characters and symbols) can be used.
(3) POP3 password
Functions
• To set the logon password for the POP3 server used for the Remote Diagnosis
System for the standard controller.
Use
• To set the logon password for the POP3 server
Setting/Procedure • The default setting is No.
• Up to 16 characters (alphanumeric characters and symbols) can be used.
(4) POP3 port number
Functions
• To set the POP3 port number used for the Remote Diagnosis System for the
standard controller.
Use
• To set the port number for the POP3 server
Setting/Procedure • The default setting is 110.
B. Receive
• These are the settings for the Receive used in the Remote Diagnosis System for the
standard controller.
(1) E-Mail Address
Functions
• To set the email address used for the Remote Diagnosis System for the standard
controller
Use
• To set the email address
Setting/Procedure • The default setting is No.
• Up to 129 characters (alphanumeric characters and symbols) can be used.
bizhub C350 Field Service Ver 2.0 April 2004
110
(0 to 65535)