bizhub C350 Field Service Ver. 2.0 April 2004
2.6.36
C0900: 2nd Drawer Lift-Up Motor Failure
Tray2 Lift-Up Sensor (PC105)
Tray2 Lift-Up Motor (M101)
Step
Check the M101 connector for proper connection
1
and correct as necessary.
Check the connector of M101 for proper drive
2
coupling and correct as necessary.
3
PC105 I/O check
M101 operation check
4
5
Change PWB-Z.
2.6.37
C0960: Manual Bypass Paper Lifting Failure
Bypass Lift-Up Sensor (PC115)
Tray2 Vertical Transport Motor (M103)
Step
Check the M103 connector for proper connection
1
and correct as necessary.
Check the connector of M103 for proper drive
2
coupling and correct as necessary.
3
PC115 I/O check
4
CL101 operation check
M103 operation check
5
6
Change PWB-Z.
Relevant Electrical Parts
Tray2 Board (PWB-Z)
Action
Relevant Electrical Parts
Tray2 Board (PWB-Z)
Action
4-37
Malfunction code
WIRING DIAGRAM
Control Signal
—
—
PWB-Z PJ6Z-3 (ON)
PWB-Z PJ4Z-4 (+)
PWB-Z PJ4Z-5 (-)
—
WIRING DIAGRAM
Control Signal
—
—
PWB-Z PJ7Z-11A (ON)
—
PWB-Z PJ5Z-5-8 (Pulse
Output)
—
Location
(Electrical
Component)
—
—
2-Y
2-U
—
Location
(Electrical
Component)
—
—
2-E
—