Image quality problem
Step
Section
The problem has been eliminated
through the checks of steps up to 9.
10
bizhub C350 Field Service Ver. 2.0 April 2004
Check Item
Result
4-90
Action
NO
Change Image Transfer Roller
Unit.
→ Change Image Transfer Belt
Unit.
→ Change MFP Control Board
→ Change High Voltage Unit/2
(Developing Bias).
→ Change High Voltage Unit/1
(Image Transfer, Neutralizing).