bizhub C350 Field Service Ver.1.0 Mar. 2004
2.3
Solution
2.3.1
C0B20:Stapling Unit Moving Motor (M6-FN) drive malfunction
A. Detection timing
Malfunction code
The Staple Home Position Sensor (PC14-FN) does not go HIGH even after the
C0B20
lapse of a given period of time after M6-FN has been energized (to return the Sta-
pling Unit to its home position).
B. Action
Staple Home Position Sensor (PC14-FN)
Stapling Unit Moving Motor (M6-FN)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PC14-FN I/O, sensor check
Turn OFF the Power Switch, move the
Stapling Unit out of its home position,
4
and turn ON the Power Switch. Opera-
tion check of the Stapling Unit Moving
Motor (M6-FN) at this time.
5
PWB-A FN replacement
Relevant electrical parts
Action
4-9
Description
Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
-
-
PWB-A FN PJ22A FN-3
-
-
Trouble code
Location
(Electrical compo-
nents)
-
-
I-7
A-4
E-5
Need help?
Do you have a question about the Bizhub C350 and is the answer not in the manual?
Questions and answers