Konica Minolta Bizhub C350 Service Manual page 207

Includes: standard controller df-601 pc-101/pc-201 pc-401 ad-501 fs-501
Hide thumbs Also See for Bizhub C350:
Table of Contents

Advertisement

bizhub C350 Field Service Ver. 2.0 April 2004
(2) Mail check
Functions
• To set whether or not to use Mail Check and the time interval for the POP3
server used for the Remote Diagnosis System for the standard controller
Use
• To select not to use Mail Check
• To change the time interval for Mail Check
Setting/Procedure • The default setting is 15 min.
(3) Connection timeout
Functions
• To set the timeout period for connection during reception
Use
• To change the timeout period for connection during reception
Setting/Procedure • The default setting is 60 sec.
C. Send
• These are the settings for the Send used in the Remote Diagnosis System for the stan-
dard controller.
(1) SMTP server
Functions
• To set the SMTP server address for transmission used for the Remote Diagnosis
System for the standard controller
Use
• To set the address of the SMTP Server
Setting/Procedure • IP Address Version 4 format
[0 to 255]. [0 to 255]. [0 to 255]. [0 to 255]
(2) SMTP port number
Functions
• To set the SMTP port number for transmission used for the Remote Diagnosis
System for the standard controller
Use
• To set the Port Number of the SMTP Server
Setting/Procedure • The default setting is 25.
(3) Timeout of SMTP Server
Functions
• To set the timeout period for transmission
Use
• To change the timeout period for connection during transmission
Setting/Procedure • The default setting is 60 sec.
15 min.
(1 to 120 min., No)
60 sec.
(30 to 300 sec.)
25
(1 to 65535)
60 sec.
(30 to 300 sec.)
3-71
TECH. REP. MODE