Includes: standard controller df-601 pc-101/pc-201 pc-401 ad-501 fs-501
Hide thumbs Also See for Bizhub C350:
Table of Contents

Advertisement

Utility Mode
(5) Box Function
Functions
• To select whether or not to use the Box function
Box function: Stores image data in the hard disk box for later use
Use
• To prohibit the use of the Box function
Setting/Procedure • The default setting is Prohibit.
C. 3/4
(1) Date & Time Setting
Functions
• To set the time-of-day, date, and time zone and start the clock.
Use
• To change the settings for time-of-day and date
• Use as part of setup procedures.
Setting/Procedure • The default setting is 00:00, January 1, 2000.
• For the time zone, set the time difference from the Greenwich Mean Time.
• The time zone can be set between -1200 and +1200 (in 30 minute intervals).
(2) Reprint
Functions
• To select whether to permit recalling and copying of image data which has previ-
ously been subjected to a copy cycle.
Use
• To prohibit Reprint
Setting/Procedure • The default setting is Yes.
(3) HDD Lock
Functions
• To select whether or not to use the HDD Lock function and, if selected to use, set
the password
• The contents of the hard disk mounted in the machine are locked using the
password.
✽ If HDD Lock has previously been set, this function is used to change the pass-
word or unlock HDD Lock.
Use
• To use the HDD Lock function
Setting/Procedure • The default setting is No.
✽ By selecting the "HDD Lock" function when the hard disk is already locked, the
password can be changed or the lock setting for the hard disk can be removed.
(4) Administrator Code Change
Functions
• To change the Administrator Code
Use
• To change the Administrator Code required for entering the Admin. Mode
Setting/Procedure • Use the 10-Key Pad to enter the new Administrator Code. 8 digits (0 to 9)
bizhub C350 Field Service Ver 2.0 April 2004
Permit
Prohibit
Yes
No
Yes
No