Parallel Setup - Genicom GEK-00027C User Manual

High duty cycle, line matrix printer
Table of Contents

Advertisement

Parallel Setup

I/F Settings
Parallel Setup
Parallel Setup
No Fault PO & OFF
Parallel Setup
TCP/IP
TCP/IP
IP Address
IP Address
000.000.000.000<
5180 User's Manual
This menu option is used to configure the parallel interface only. The
option No Fault PO & Off, under this menu may be enabled or
disabled. In the default condition (disabled), the parallel fault lead
will be set to true for either of the two conditions, paper out or if in
the offline condition. If enabled, the parallel fault lead will not be set
to true for either (or both) of the conditions, paper out and/or offline.
The TCP/IP options is a compatibility option for Genicom 4810/4840
printers. The IP Address, Netmask and Router IP Address of Genicom
models 98-205-153 and 98-305-153 NIC print servers may be
programmed via the control panel menu using the IEEE1284 parallel
interface. This feature is restricted to these specific Genicom model
ethernet print servers and as such utilizes a proprietary Genicom
protocol that differs from the bi-directional 1284 protocol
specifications.
1. While in the I/F Settings menu, press the ◄ (left) or ► (right)
menu browse key until Parallel Setup is displayed in the lower
right corner of the LCD.
2. Press the ▼ (down) menu browse key to select Parallel Setup.
Parallel Setup will be displayed in the upper left corner of the
display and the current setting will be displayed in the lower right
corner of the display.
3. Press the Select key to enable or disable the setting. The < symbol
will now immediately follow the enabled setting.
To set the IP Address, or Router IP Address, use the following
procedures:
1. While in the Parallel Setup options, press the ◄ (left) or ► (right)
menu browse keys until TCP/IP is displayed in the lower right
corner of the LCD.
2. Press the Select key. TCP/IP will be displayed in the upper left
corner of the LCD.
3. Press the ◄ (left) or ► (right) menu browse keys until IP Address,
Netmask or Router IP Addr is displayed in the lower right corner of
the LCD. (The example to the left is for the IP Address setting.)
4. Press the Select key. Notice the cursor (underline) is now shown
under the first digit. The horizontal ◄ ► (left or right) menu
browse keys position the cursor (underline) under the digit to be
changed; the vertical ▲ ▼ (up or down) increment/decrement the
selected digit by one.
5. Press the Clear key after all changes are complete and the
desired value is displayed in the lower right corner of the LCD.
Pressing the Clear key does not erase the values entered, but does
allow the user to exit the User Set menu.
Repeat this section if further changes are necessary. Cycle power
after entries to activate changes.
Note
72
GEK-00028C

Advertisement

Table of Contents
loading

This manual is also suitable for:

5180