5180 User's Manual
The Auto Funct option is used to specify what action will be taken
when the printing of an IBM print buffer is completed. If set to FF
(form feed), the printer will automatically execute a form feed at the
end of the print buffer or a local copy, unless the last character
received was a form feed. If set to NL (new line), and the last
character received is not a form feed, new line, or carriage return, a
new line will be automatically executed.
1. While in the Coax Compat menu, press the ◄ (left) or ► (right)
menu browse keys until Auto Funct is displayed in the lower right
corner of the display.
2. Press the ▼ (down) menu browse key to access the Auto Funct
options.
3. Press the ◄ (left) or ► (right) menu browse key until the desired
option is displayed. Press the Select key to enable or disable an
option. The < symbol will immediately follow an enabled option.
This enables/disables LAST LF/FF (Last Line Feed Send as Form
Feed). When enabled, this option will cause a form feed when the last
character in the IBM print buffer is a line feed.
1. While in the Coax Compat menu, press the ◄ (left) or ► (right)
menu browse keys until LAST LF/FF is displayed in the lower
right corner of the display.
2. Press the ▼ (down) menu browse key to access the LAST LF/FF
options.
3. Press the ◄ (left) or ► (right) menu browse key until the desired
option is displayed. Press the Select key to enable or disable an
option. The < symbol will immediately follow an enabled option.
This enables/disables Supp CCode (Suppress Host Control Codes).
When enabled, suppresses control codes generated by the IBM host.
1. While in the Coax Compat menu, press the ◄ (left) or ► (right)
menu browse keys until Supp CCode is displayed in the lower
right corner of the display.
2. Press the ▼ (down) menu browse key to access the Supp CCode
options.
3. Press the ◄ (left) or ► (right) menu browse key until the desired
option is displayed. Press the Select key to enable or disable an
option. The < symbol will immediately follow an enabled option.