Garp Port Configuration; Figure 129: Garp Port Configuration; Table 112: Garp Port Configuration Fields - D-Link DWS-4026 User Manual

Dws-4000 series unified wired & wireless access system
Table of Contents

Advertisement

Software User Manual
12/10/09
GARP P
C
ORT
ONFIGURATION
Use the GARP Port Configuration page to configure GARP settings for a specific interface.
To access the GARP Port Configuration page, click LAN > L2 Features > GARP > Port Configuration in the navigation
tree.
Field
Slot/Port
Port GVRP Mode
Port GMRP Mode
GARP Timers
GARP Join Timer (centisecs)
GARP Leave Timer (centisecs) Displays time lapse, in centiseconds, that the switch waits before leaving its GARP
Document
34CSFP6XXUWS-SWUM100-D7

Figure 129: GARP Port Configuration

Table 112: GARP Port Configuration Fields

Description
Specifies interface on which to configure the GARP settings. If you select All from the
drop-down menu, the settings on the page affect all interfaces.
Choose the GARP VLAN Registration Protocol administrative mode for the port by
selecting enable or disable from the pulldown menu.If you select disable, the protocol
will not be active and the Join Time, Leave Time and Leave All Time will have no effect.
The factory default is disable.
Choose the GARP Multicast Registration Protocol administrative mode for the port by
selecting enable or disable from the pulldown menu. If you select disable, the protocol
will not be active, and Join Time, Leave Time and Leave All Time have no effect. The
factory default is disable.
Specify the time between the transmission of GARP PDUs registering (or re-
registering) membership for a VLAN or multicast group in centiseconds. Enter a
number between 10 and 100 (0.1 to 1.0 seconds). The factory default is 20
centiseconds (0.2 seconds). An instance of this timer exists for each GARP participant
for each port.
state. Leave time is activated by a Leave All Time message sent/received, and
cancelled by the Join message received.This allows time for another station to assert
registration for the same attribute in order to maintain uninterrupted service. Enter a
number between 20 and 600 (0.2 to 6.0 seconds). Leave time must be greater than or
equal to three times the join time. The factory default is 60 centiseconds (0.6 seconds).
An instance of this timer exists for each GARP participant for each port.
D-Link Unified Access System
Configuring GARP
Page 207

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwl-8600apDws-4000 series

Table of Contents