Configuring Users In A Remote Radius Server; Table 229: Local User Configuration; Table 230: Captive Portal User Radius Attributes - D-Link DWS-4026 User Manual

Dws-4000 series unified wired & wireless access system
Table of Contents

Advertisement

D-Link Unified Access System
Field
Description
Max Up Rate
Enter the maximum speed, in bytes per second, that the user can transmit traffic when using the
captive portal. This setting limits the bandwidth at which the user can send data into the network.
Max Down Rate
Enter the maximum speed, in bytes per second, that the user can receive traffic when using the
captive portal. This setting limits the bandwidth at which the user can receive data from the
network.
Max Receive
Enter the maximum number of bytes that the user is allowed to receive when using the captive
portal. After this limit has been reached the user will be disconnected.
Max Transmit
Enter the maximum number of bytes that the user is allowed to transmit when using the captive
portal. After this limit has been reached the user will be disconnected.
Max Total
Enter the maximum number of bytes the user is allowed to transfer (sum of bytes transmitted and
received). After this limit has been reached the user will be disconnected.

Configuring Users in a Remote RADIUS Server

You can use a remote RADIUS server client authorization. You must add all users to the RADIUS server. The local database
in the Unified Switch does not share any information with the remote RADIUS database.
Table 230
indicates the RADIUS attributes you use to configure authorized captive portal clients. The table indicates both
RADIUS attributes and vendor-specific attributes (VSA). VSAs are denoted in the Attribute column and are comma delimited
(vendor id, attribute id).
Attribute
Number
User-Name
1
User-Password
2
Session-Timeout
27
Idle-Timeout
28
WISPr-Bandwidth-
14122, 7
Max-Up
Page 372
Captive Portal Configuration

Table 229: Local User Configuration

Table 230: Captive Portal User RADIUS Attributes

Description
User name to be authorized
User password
Logout once session timeout is
reached (seconds). If the
attribute is 0 or not present then
use the value configured for the
captive portal.
Logout once idle timeout is
reached (seconds). If the
attribute is 0 or not present then
use the value configured for the
captive portal.
Maximum client transmit rate
(b/s). Limits the bandwidth at
which the client can send data
into the network. If the attribute
is 0 or not present, then use the
value configured for the captive
portal.
Software User Manual
Range
Usage
1-32
Required
characters
8-64
Required
characters
Integer
Optional
(seconds)
Integer
Optional
(seconds)
Integer
Optional
Document 34CSFP6XXUWS-SWUM100-D7
12/10/09
Default
None
None