Error Troubleshooting

Sub System Check

DC676 Adjust ROS
The DC671 Regi Measure routine corrects the ROS Lead Regi Parameter when the ROS Assembly has
been replaced.
1.
Enter Service Diagnostics menu
2.
Press Down Arrow and navigate to
Press Right Arrow to display the
3.
Press Down Arrow and navigate to
4.
Press Right Arrow to display the
5.
Press OK to run the ROS Exposure Point Adjustment. As the process is running, the
6.
ROS - In progress
When the process has completed successfully, the
displayed.
If the process has completed with error, the
displayed.
7.
Press Menu to return to the
2-52
Phaser 7100 Service Manual
(Entering Service Diagnostics
Subsystem
Subsystem Check DC671 RegiMeasure
Subsystem Check DC676 Adjust
DC676 Adjust ROS - Press OK to run
screen is displayed.
Diagnostics - Adjustment
on page 2-14).
Check.
DC676 Adjust ROS - Completed
DC676 Adjust ROS - Completed-Error
menu screen.
screen.
ROS.
screen.
DC676 Adjust
screen is
screen is
Xerox Internal Use Only