Adjustment

DC131 NVM Read/ Write
The DC131 NVM Read/ Write routine provides access to read and modify specific NVM values within
the I/P Board and access and read IOT NVM.
CAUTION:
Be careful when making changes to the NVM value. Always write down the original
NVM value (for reference) prior to making any changes. Incorrect changes to an NVM value could
make the printer inoperable.
1.
Enter Service Diagnostics menu
2.
Press Down Arrow and navigate to
Press Right Arrow and navigate to
3.
Press Right Arrow to display the
4.
Note:
To set the Chain-Link No., use Left/ Right Arrow to move the cursor and Down/ Up Arrow to
change the number.
Note:
When the cursor is at the left end of the Chain-Link No., pressing Left Arrow returns to the
Adjustment - DC131 NVM R/W
Press OK to confirm the Chain-Link No.
5.
If the Chain-Link No. is applicable, the current NVM value and the cursor will be displayed.
If the Chain-Link No. is not applicable, the NG screen will be displayed. Press OK to return to the
Chain-Link No. input screen.
6.
To change the current NVM value, use Left/ Right to move the cursor and Down/ Up Arrow to
change the number.
Xerox Internal Use Only
(Entering Service Diagnostics
Diagnostics
Adjustment.
Adjustment DC131 NVM
DC131 NVM R/W 000-000
screen at the previous level.
Error Troubleshooting
on page 2-14).
R/W.
Chain-Link No. input screen.
Phaser 7100 Service Manual
2-45