Service Parts Disassembly

REP 4.2 DRW Fuser Harness Assembly

PL 4.1.7
WARNING:
The Fuser may be hot. Turn the printer power Off and allow at least 30 minutes for
the Fuser to cool before removing the Fuser.
1.
Remove Tray 1.
2.
Remove the Fuser Unit
3.
Remove the I/P PWB Cover Assembly
page 4-19).
4.
Remove the Rear Cover
5.
Remove the Left Side Cover
6.
Remove the Left Feeder Cover
7.
Remove the Control Panel Assembly
8.
Remove the Bypass Tray Assembly
9.
Remove the Bypass Tray Cover
page 4-71).
10. Remove the Front Cover Assembly
4-80
Phaser 7100 Service Manual
(REP 10.1 Fuser Unit
on page 4-183).
(REP 1.5 Image Processor (I/P) PWB Cover Assembly
(REP 1.6 Rear Cover
on page 4-20).
(REP 1.10 Left Side Cover
(REP 2.10 Left Feeder Cover
(REP 1.12 Control Panel Assembly
(REP 3.5 Bypass Tray Assembly
(REP 3.3 Bypass Tray Cover Assembly/ Exit 1 Cover/ Exit 2 Cover
(REP 1.15 Front Cover Assembly
on page 4-25).
on page 4-49).
on page 4-29).
on page 4-73).
on page 4-35).
on
on