124-344 All Billings Meter/ 124-346 All Billings Count Types Mismatch
Billing error has occurred due to one of the following problems.
•
The Billing Meter Types that are stored in multiple locations are all different.
•
The Billing Count Types that are stored in multiple locations are all different.
Applicable Fault Codes
•
124-344: Billing Meter Type Fail (different at all 3 locations)
•
124-346: Billing Count Type Fail (different at all 3 locations)
Initial Actions
•
Power cycle the printer.
•
If the problem persists, perform the following procedure
Troubleshooting Reference
Applicable Parts
• MCU PWB, PL 12.1.15
• Image Processor PWB, PL 12.4.1
Troubleshooting Procedure
Step
Actions and Questions
1.
Replace the MCU PWB
2.
If the problem persists, replace the I/P PWB
Xerox Internal Use Only
(REP 12.4 MCU PWB
on page 4-206).
(REP 12.17 Image Processor (I/P) PWB
.
Wiring and Plug/Jack Map References
Phaser 7100 Service Manual 2-391
Error Troubleshooting
on page 4-228).