116-395 USB Soft Fail

A USB-related fatal error. A problem has occurred in the software processing and it is unable to
continue with the subsequent processes.
Applicable Fault Code
116-395: A USB-related Fatal Error
Initial Actions
Power cycle the printer.
If the problem persists, perform the following procedure
Troubleshooting Procedure
Step
Actions and Questions
1.
Turn the printer power Off and On and check whether the problem is reoccurring.
If the problem persists, go to

116-396 FIPS140 Self Test Fail

During start up, an error was detected by the self test of the FIPS140 certificate encryption module.
Self test error due to invalid ROM (FW).
Applicable Fault Code
116-396: <FIPS140 Self Test Fail> During start up, an error was detected by the self test of the
FIPS140 encryption module.
Initial Actions
Power cycle the printer.
If the problem persists, perform the following procedure
Troubleshooting Procedure
Step
Actions and Questions
1.
Replace the ROM (FW) or upload again.
2-356
Phaser 7100 Service Manual
Network Troubleshooting
.
on page 2-459.
.